As Sonet/SDH evolve to the next generation, new devices eg:
Multi Service Switching Platforms (MSSP) and Multi Service
Provisioning Platforms (MSPP) are being implemented to meet
the new demands made by the increasing range of data types
and bandwidths that need to be transported.
To meet changes in the structure of the network that these
new devices bring, different test methodologies are required
to verify that the network continues to function when things
go wrong. The netwok is extremely complex, and many things
can go wrong at the same time. A simple point-to-point test
is no longer adequate to verify robustness under all operating
conditions.
The Agilent N2X meets these new test challenges head-on with
a truly scalable test solution that allows exhaustive and
simultaneous testing of a large number of ports and parths
through a network.
MSP Performance Varies Under Load
Just as a router's performance varies under load, so does
the performance of a Multi Service Platform (MSP). Before
carrying customer traffic, service providers will evaluate
MSPs to ensure their networks will perform under real-life
load conditions. The scalability of the Agilent N2X lets users
test as many ports as needed with every error, every alarm
and every service disruption on all paths being measured simultaneously
in real time. Only Agilent N2X can truly characterise the
robustness of a MSP under all load conditions.
Powerful Protection Switching Testing
Simultaneous APS time measurement of all channels lets you
view the impact of a fiber break on all of the affected channels/paths
carried on that fiber. Also, simultaneous monitoring of all
J1/J2 messages highlights any provisioning problems resulting
from a fiber break. The OmniBER XM lets you see exactly how
SONET/SDH problems impact your clients services.
Iometrix Proves MSP Loading Affects APS Performance
Iometrix test laboratory
used the N2X Multi-Services Transport Application and XM Test
Cards "...to put together the largest stress test ever
conducted on a metro SONET networ" with ...512 STS-3C
circuits, 160Gb/s of traffic and 80 Gb/s of simultaneous service
disruption". The test showed that protection switching
times were directly affected by the loading and mix of payloads
carried in the network. For teh full report, visit the
Iometrix website.
Next Generation Payloads
The N2X Multi-Services Transport application provides simple
setup of complex mapping structures enabling the simulation
of real-life traffic structures. Any valid mix of AU-4-nc/STS-nc,
can be quickly constructed on the simple to use graphical
user interface. Catch any possible problem, regardless of
the type of data the network carrys.
More Information
-
Technical Datasheet
- Brochures
- Demos
|
Member of
|
|